| $13,041.05 | ||||
| Item(s) | Required | Type/Description | Make | Model No. |
| Battery Box (Note 1) | 1 | 18”x30”x26” | Direct Power | HDPE |
| Batteries | 8 | 420 AH X 2 | Trojan | L-16HC |
| Battery Cables (Note 2) | 2 | Battery Interconnect | Various | BC4 |
| Battery Equalizer | 1 | 20 Amp | Solar Converter | EQ12/24-20 |
| Power Vent | 1 | Battery Box Ventilator | Zephyr | 24 Volt |
| Battery Temp Sensor | 1 | Temp Sensor | Xantrex | BTS-15 |
| Dump Load (Note 8) | 1 | 1200 Watt Immersion | TPD | DL1200W |
| Charge Controller | 1 | 60 Amp | Xantrex | C60 |
| CC Remote Meter | 1 | CC Monitor | Xantrex | CM/R-50 |
| Inverter(s) | 2 | Modified Sine Wave | Xantrex | DR2424 |
| Inverter Controller | 1 | Digital Controller | Xantrex | RC-8 |
| Inverter Cables | 1 | Link Cable | Xantrex | DRI Cable |
| Wind Generator (Note 7) | 1 | 24 Volt Wind Generator | SW Wind Power | Whisper 200 |
| Wind Generator Tower | 1 | 30' Guyed Tower Kit | SW Wind Power | Whisper 200 |
| Generator (Gas) | 1 | 24 VDC 70 A Genset | TPD | G-24-70 |
| Protective Gear (Note 4) | 1 | Fuses & Holders | Various | FK1 |
| Wire (Note 5) | 1 | THHN Industrial Grade | Various | Wire |
| Wiring Devices (Note 6) | 1 | Industrial Grade | Various | WDK1 |
| Prices Subject To Change Without Notice | ||||
| Note 1: Primed and ready to paint. | ||||
| Note 2: All battery cables are 1/0 wire. | ||||
| Note 3: Generator Start Module automatically starts an electric start | ||||
| generator if battery voltage falls below a set voltage and | ||||
| shuts the generator down when battery reaches full charge | ||||
| This is desirable in cases where there is no sun or wind for an | ||||
| extended period of time. Appropriate generator sets are | ||||
| Available from TPD Ltd or may be customer supplied. | ||||
| Note 4: All required fuses and breakers supplied and installed. | ||||
| One set of extra fuses supplied. | ||||
| Note 5: All wire is high quality industrial grade type THHN. | ||||
| Note 6: All wiring boxes, etc. are high quality industrial grade. | ||||
| Note 7: It may be necessary to use a taller tower and/or | ||||
| Additional guy wires, anchors, etc. at additional cost. | ||||
| Note 8: A resistive dump load is required for dissipating power | ||||
| generated by the solar panels or wind generator once the batteries | ||||
| Have reached full charge in order to avoid damaging the batteries | ||||
| by overcharging them. These are available in both air and water | ||||
| heating types. | ||||